Power Configuration
400V, 3-Phase Wye (L-N), 22.2kVA, 32A
Features
- 60°C; 10kAIC Breakers; Branch Current Monitoring
Energy Metering
- Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power Factor
Metering Accuracy
- Class 0.5 meter
Metering Capabilities
- Per Input Line: Yes
- Per Branch Circuit Breaker: Yes
- Per Output Receptacle: Yes
Remote Outlet Switching: Yes
Power Quality Monitoring
- Voltage and Current Harmonic Distortion
- Distortion Power Factor
- Voltage Dip and Swell
- Neutral Current, Current Inrush, Crest Factor
Outlet Power Distribution: Alternating Branch
Replaceable Controller: Yes, hot-swappable
Environmental Sensor Ready: Yes
Compatible Sensors
- Temperature, Humidity, Air Flow, Differential Pressure, Dust/Particle, Water Leak, Proximity/Motion, Vibration, Dry Contact, Contact Closure
PDU Linking
- Link up to 8 PDUs with shared knowledge and power information from attached Expansion PDUs.
- Redundant power from the first expansion unit ensures uptime even if the Primary PDU loses power.
Cascading
- Physically cascade up to 32 PDUs under one ethernet port or 16 PDUs with USB using bridging mode.
- Save IP addresses by using a single IP address with port forwarding.
Linking Capabilities
- Maximum of 8 PDUs can be linked using the PDU Link Port.
- PDU 1 serves as the Primary, linking up to 7 additional PDUs (Link PDUs), totaling 8.
Networking
- (10/100/1000 Base T) Ethernet, Secondary redundant (10/100/1000 Base T) Ethernet
- Optional WiFi (802.11 a/b/g/n)
Remote Management
- HTTP(s), SSH (CLI), Telnet, RS-232 (Serial), SNMP v2/v3, SMTP, JSON-RPC API, MODBUS-TCP, Redfish API
Onboard Display
- Color matrix LCD display showing voltage, current, or active power (per line, breaker, or outlet); alarms; configuration information (name, ratings, IP/networking). Auto-flip orientation.
Specifications
Input
- Input Plug: 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr
- Nominal Voltage: 400V
- Maximum Input Current: 32A
- Rated Input Current: 32A
- Power Capacity: 22.2kVA
- Cord Length: 3m
Output
- Receptacles: (12) C13, (12) C19, (12) Cx
- Overload Protection: 6
Physical
- Dimensions (WxDxH): 56mm x 65mm x 1539mm
- Unit Weight: 15 lbs
- Shipping Weight: 20.72 lbs
- Shipping Dimensions: 1700mm x 255mm x 125mm
- Mounting: G4-HOLDER-FOR-ZU
Environmental
- Operating Temperature: 60°C
- Operating Relative Humidity: 85%
- Operating Elevation: 0-10,000 ft
Conformance
- Regulatory Approvals: CE
- Warranty: Standard 2-year manufacturer warranty