Introducing... The Raritan PX4 Rack PDU
|
|
Time to read 1 min
|
|
Time to read 1 min
The Power of Forward Thinking
The Intersection of Innovation and Proven Performance
The PX4 continues the Raritan legacy of delivering best-in-class intelligence while introducing a set of industry-proven hardware and outlet technology. This unmatched feature-set delivers density, flexibility, and reliability to drive operational excellence.
> Real-time visibility, reporting, and alerting of power metrics
> Best-in-class flexibility
> Engineered for mission-critical uptime
> Unsurpassed outlet and power density
> Easy data collection and export for energy utilization
> Secure encrypted communication for all PDU data
Remove unnecessary outlet molding with the patented High Density Outlet Technology (HDOT), providing the most
outlets per PDU form factor to support high-density rack
requirements.
Reduce complexity, increase flexibility, and simplify the PDU selection process with a hybrid of C13 and C19 outlets. Accommodating both C20 and C14 power cables in a single
outlet while lowering costs and future-proofing installations.
Make installation easier with the Ramlock Locking Technology, including auto-lock and a manual release lever allowing easy unplugging.
Experience faster installation and easier load balancing with Alternating Branch Outlets that repeat on a distinguishable pattern over the PDU; Lessening out-of-balance loads and therefore reducing heating risks.
Save money and time by utilising the one-size-fits-all feature; the 45-Degree Angled Infeed includes a flexible infeed cord design, bottom or front entries and a bend radius with no performance degradation.
Make maintenance simpler by easily and quickly identifying the PDU health status. With R/G/B LED Indicators showing conditions including outlet power and suspect circuit breakers.
Make outlet switching safer using the Bi-Stable Latching Relays. In the rare case of a PDU failure, relays configure to the on/off state to maintain critical power whilst also consuming less energy and minimizing inrush current overloads.
Operate safely and reliably thanks to the Industrial Grade Mechanical Design. Built with a 60°C standard
temperature rating, the PX4 withstands dense, high heat environments to conduct reliable performance.
Benefitting from 30+ years of battle-tested engineering, Raritan users experience perfected PDUs thanks to dedicated data centre experts who work to ensure uptime and availability.
Adding Xerus™ Technology Platform to industry-proven outlet technology to create a set of ground-breaking intelligence features.
With the ability to find and configure the PX4 to suit your solution; We are on-hand to assist you with anything from a standard configuration model, a configure-to-order model, or by engineering a custom PDU designed to your specific needs.
Outpace | Outthink | Outperform