{"title":"Fluke OLTS","description":"","products":[{"product_id":"fluke-networks-certifiber-pro-cfp-q-add","title":"Fluke Networks CertiFiber Pro Add on Kit - CFP-Q-ADD","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eFluke Networks CertiFiber Pro add on kit improves the efficiency of fibre optics. The Taptive user interface simplifies set-up, eliminates errors and speeds troubleshooting. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eVersiv enables users to accomplish more than ever before with a cable tester, accelerating every step of the testing process\u003c\/li\u003e\n\u003cli\u003eProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time.\u003c\/li\u003e\n\u003cli\u003eTaptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels.\u003c\/li\u003e\n\u003cli\u003eLinkWare management software provides unmatched analysis of test results and professional test reports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke Networks CertiFiber Pro Add on Kit includes\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e2 CertiFiber Pro Quad OLTS Modules\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSC\/LC EF-compliant MM TRC Kit 50 µm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSC\/LC SM TRC Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTRC Carrying Case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e2 LC\/LC Simplex Adaptors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLarge Carry Case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVersiv Open Source Software CD\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStatement of Calibration and Getting Started Guide\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eGot any questions? \u003c\/strong\u003e\u003cstrong\u003eCall 01403 756588 during office hours to speak to a team member about the Fluke Networks CertiFibre Pro.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":49450772889896,"sku":"CFP-Q-ADD","price":10155.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/Untitled_design_-_2025-08-08T104614.515.png?v=1754646383"},{"product_id":"fluke-networks-certifiber-pro-cfp-100-q-int","title":"Fluke Networks CertiFiber® Pro - CFP2-100-Q-INT","description":"\u003cp\u003e\u003cspan\u003eThe Fluke Networks CertiFiber ProQ improves the efficiency of fibre optics certification and includes 1 Versiv Mainframe \u0026amp; Remote and 2 CertiFiber Pro Multimode OLTS Modules. The Taptive user interface simplifies set-up, eliminates errors and speeds troubleshooting. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eVersiv enables users to accomplish more than ever before with a cable tester, accelerating every step of the testing process\u003c\/li\u003e\n\u003cli\u003eProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time.\u003c\/li\u003e\n\u003cli\u003eTaptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels.\u003c\/li\u003e\n\u003cli\u003eLinkWare management software provides unmatched analysis of test results and professional test reports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eCertiFiber Pro’s Optical Loss Test Set (OLTS) double ended fibre optic inspection capability allows you to inspect and certify fiber optic connector end-faces at both ends of your fiber link in less than a second so you can get your job done the first time. This double ended fibre optic inspection capability provides automated PASS\/FAIL certification, takes the guesswork out of fibre inspection so anyone can be a fiber expert.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eGot any questions? \u003c\/strong\u003e\u003cstrong\u003eCall 01403 756588 during office hours to speak to a team member about the Fluke Networks CertiFibre Pro.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOptical loss test set with fastest time to certify – two fibres at two wavelengths in three seconds.\u003c\/li\u003e\n\u003cli\u003eEncircled Flux compliant as required by ANSI\/TIA and ISO\/IEC\u003c\/li\u003e\n\u003cli\u003eMerged Tier 1 (Basic) \/ Tier 2 (Extended) testing and reporting when paired with OptiFiber® Pro OTDR\u003c\/li\u003e\n\u003cli\u003eProjX™ management system ensures all jobs are completed correctly and efficiently\u003c\/li\u003e\n\u003cli\u003eOptical loss test set provides automatic Pass\/Fail analysis to industry standards or custom test limits\u003c\/li\u003e\n\u003cli\u003eDouble ended Pass\/Fail certification of fibre optic connector end faces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" id=\"ui-accordion-1-panel-0\" aria-labelledby=\"ui-accordion-1-header-0\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" aria-labelledby=\"ui-accordion-1-header-1\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" id=\"ui-accordion-1-panel-5\" aria-labelledby=\"ui-accordion-1-header-5\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ctable border=\"0\" cellpadding=\"2\" cellspacing=\"0\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#cccccc\" colspan=\"2\"\u003e\u003cstrong\u003ePower Meter Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003eInput Connector\u003c\/td\u003e\n\u003ctd\u003eInterchangeable connector adapter (LC standard, SC, ST and FC optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003eDetector Type\u003c\/td\u003e\n\u003ctd\u003eInGaAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003eWavelengths\u003c\/td\u003e\n\u003ctd\u003e850 nm, 1300 nm, 1310 nm, 1550 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003ePower Measurement Range\u003c\/td\u003e\n\u003ctd\u003e0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003ePower Measurement Uncertainty\u003csup\u003e1,2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; +\/- 5% +\/- 32 pW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003eMeasurement Linearity\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; ± 0.1 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003eRe-calibration Period\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003eIntegrated Wi-Fi\u003c\/td\u003e\n\u003ctd\u003eMeets IEEE 802.11 a\/b\/g\/n; dual band (2.4 GHz and 5 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan class=\"legal\"\u003e\u003cspan size=\"1\" style=\"font-size: xx-small;\"\u003e1. +\/- 100 pW at 850 nm\u003cbr\u003e2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50\/125 μm and NA = 0.14 for 9\/125 μm. Ambient temperature 23° ± 1°C. SC\/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST.\u003cbr\u003e3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5 minute warm-up.\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":49450734223656,"sku":"CFP2-100-Q-INT","price":13053.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/Untitled_design_-_2025-08-11T093441.602.png?v=1754901359"},{"product_id":"fluke-networks-certifiber-pro-cfp2-100-s","title":"Fluke Networks CertiFiber® Pro - CFP2-100-S-INT","description":"\u003cp\u003e\u003cspan\u003eThe Fluke Networks CertiFiber ProQI improves the efficiency of fibre optics certification and includes 1 Versiv Mainframe \u0026amp; Remote and 2 CertiFiber Pro Singlemode OLTS modules. The Taptive user interface simplifies set-up, eliminates errors and speeds troubleshooting. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eVersiv enables users to accomplish more than ever before with a cable tester, accelerating every step of the testing process\u003c\/li\u003e\n\u003cli\u003eProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time.\u003c\/li\u003e\n\u003cli\u003eTaptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels.\u003c\/li\u003e\n\u003cli\u003eLinkWare management software provides unmatched analysis of test results and professional test reports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eCertiFiber Pro’s Optical Loss Test Set (OLTS) double ended fibre optic inspection capability allows you to inspect and certify fiber optic connector end-faces at both ends of your fiber link in less than a second so you can get your job done the first time. This double ended fibre optic inspection capability provides automated PASS\/FAIL certification, takes the guesswork out of fibre inspection so anyone can be a fiber expert.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eGot any questions? \u003c\/strong\u003e\u003cstrong\u003eCall 01403 756588 during office hours to speak to a team member about the Fluke Networks CertiFibre Pro.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOptical loss test set with fastest time to certify – two fibres at two wavelengths in three seconds.\u003c\/li\u003e\n\u003cli\u003eEncircled Flux compliant as required by ANSI\/TIA and ISO\/IEC\u003c\/li\u003e\n\u003cli\u003eMerged Tier 1 (Basic) \/ Tier 2 (Extended) testing and reporting when paired with OptiFiber® Pro OTDR\u003c\/li\u003e\n\u003cli\u003eProjX™ management system ensures all jobs are completed correctly and efficiently\u003c\/li\u003e\n\u003cli\u003eOptical loss test set provides automatic Pass\/Fail analysis to industry standards or custom test limits\u003c\/li\u003e\n\u003cli\u003eDouble ended Pass\/Fail certification of fibre optic connector end faces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" id=\"ui-accordion-1-panel-0\" aria-labelledby=\"ui-accordion-1-header-0\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" aria-labelledby=\"ui-accordion-1-header-1\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" id=\"ui-accordion-1-panel-5\" aria-labelledby=\"ui-accordion-1-header-5\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ctable border=\"0\" cellpadding=\"2\" cellspacing=\"0\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#cccccc\" colspan=\"2\"\u003e\u003cstrong\u003ePower Meter Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003eInput Connector\u003c\/td\u003e\n\u003ctd\u003eInterchangeable connector adapter (LC standard, SC, ST and FC optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003eDetector Type\u003c\/td\u003e\n\u003ctd\u003eInGaAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003eWavelengths\u003c\/td\u003e\n\u003ctd\u003e850 nm, 1300 nm, 1310 nm, 1550 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003ePower Measurement Range\u003c\/td\u003e\n\u003ctd\u003e0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003ePower Measurement Uncertainty\u003csup\u003e1,2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; +\/- 5% +\/- 32 pW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003eMeasurement Linearity\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; ± 0.1 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003eRe-calibration Period\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003eIntegrated Wi-Fi\u003c\/td\u003e\n\u003ctd\u003eMeets IEEE 802.11 a\/b\/g\/n; dual band (2.4 GHz and 5 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan class=\"legal\"\u003e\u003cspan size=\"1\" style=\"font-size: xx-small;\"\u003e1. +\/- 100 pW at 850 nm\u003cbr\u003e2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50\/125 μm and NA = 0.14 for 9\/125 μm. Ambient temperature 23° ± 1°C. SC\/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST.\u003cbr\u003e3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5 minute warm-up.\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":49450732159272,"sku":"CFP2-100-S-INT","price":11233.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/Fn-cfp-100-s.jpg?v=1723108915"},{"product_id":"fluke-ftk1000","title":"Fluke Networks Multimode Fibre Test Kit - FTK1000","description":"\u003cp\u003eFluke Networks Fiber Test Kit includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimpliFiber Pro optical power meter\u003c\/li\u003e\n\u003cli\u003e850\/1300 multimode source\u003c\/li\u003e\n\u003cli\u003eCarrying case\u003c\/li\u003e\n\u003cli\u003eSC power-meter adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #0000ff;\"\u003eGot any questions about the Fibre Test Kit? Please call our team during office hours on 01403 756588.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimpliFiber Pro Kit Configurations\u003c\/li\u003e\n\u003cli\u003eFiber Inspection\u003c\/li\u003e\n\u003cli\u003eFiber Cleaning\u003c\/li\u003e\n\u003cli\u003eResults Management\u003c\/li\u003e\n\u003cli\u003eVerify and Locate Faults\u003c\/li\u003e\n\u003cli\u003eUnique Capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable1\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-10º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-20º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e95% (10º C to 35º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003e75% (35º C to 40º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003eUncontrolled \u0026lt;10º C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eEMI, RFI, EMC\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eStandards compliant\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eConforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable2\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eOptical Power Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDetector Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eInGaAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCalibrated Wavelengths\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e+10 to -52 dBm (850 nm)\u003c\/li\u003e\n\u003cli\u003e+10 to -60 dBm (1300, 1310, 1490, 1550, 1625 nm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Linearity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e±0.2 dB (850 nm)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e±0.1 dB (1300, 1310, 1490, 1550, 1625 nm)\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Uncertainty\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.25 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay Resolution, dB or dBm\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e0.01 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Display Units\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003edBm, mW, μW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto-Wavelength Detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eData Storage\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1000 records, multiple wavelengths per record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eExternal Interface\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eUSB, 2.0 full speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eRemovable adapter, SC adapter as default, optional adapters include LC, ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay update rate\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1 reading per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eReference\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eIndividually set for each wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber ID detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\u0026gt; 50 Hours (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e10, 20, 30 or 60 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, low battery icon blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e11.5 oz (325 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power \u0026lt; -45 dBm\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power \u0026gt; 0 dBm and \u0026lt; -55 dBm\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23°C ±2°C, power level -20dBm, continuous wave, 62.5\/125µm at multi mode wavelengths, 9\/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm,\u003cbr\u003e\u003csup\u003e4\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable3\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eMultimode Optical Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCentral Wavelength\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: +\/-30 nm\u003c\/li\u003e\n\u003cli\u003e1300 nm: +\/- 20 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSpectral Width (FWHM)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: 50 nm (typical)\u003c\/li\u003e\n\u003cli\u003e1300 nm: 135 nm (typical)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMinimum Output Power\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850\/1300 nm:\u003cspan\u003e \u003c\/span\u003e\u003cspan face=\"Arial\" size=\"2\"\u003e\u003cspan face=\"Symbol\" size=\"2\"\u003e³\u003c\/span\u003e\u003cspan size=\"2\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-20 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Output Stability\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.1 dB over 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Can be enabled\/disabled by\u003cspan\u003e \u003c\/span\u003euser.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Output Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Fixed at ID 1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eModes\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eCW, 2 kHz modulated, Auto-wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e40 hrs (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, LED blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1.8 oz (278 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23° C ± 2° C, after 5 minutes warm-up time\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003eauto-wavelength\u003cspan\u003e \u003c\/span\u003emode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":49450936369448,"sku":"FTK1000","price":2429.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/Untitled_design_-_2025-08-08T111246.073.png?v=1754647982"},{"product_id":"fluke-ftk1375","title":"Fluke Networks Fiber Test Kits - FTK1375","description":"\u003cp\u003e\u003cspan\u003eFluke Networks Fiber Test Kits - FTK1375; \u003c\/span\u003e\u003cspan\u003eMultimode Fiber Verification Kit with FI-500 FiberInspector Micro. Includes:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSimpliFiber Pro optical power meter, 850\/1300 multimode source, VisiFault VFL, FI-500 FiberInspector, FindFiber Remote ID source, and carrying case; SC, ST, and LC power meter adapters\u003c\/span\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\" data-mce-style=\"color: #0000ff;\"\u003e\u003cstrong\u003eGot any questions about the Fluke Networks Fibre Test Kit FTK 1375? Please call our team during office hours on 01403 756588\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimpliFiber Pro Kit Configurations\u003c\/li\u003e\n\u003cli\u003eFiber Inspection\u003c\/li\u003e\n\u003cli\u003eResults Management\u003c\/li\u003e\n\u003cli\u003eVerify and Locate Faults\u003c\/li\u003e\n\u003cli\u003eUnique Capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable1\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-10º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-20º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e95% (10º C to 35º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003e75% (35º C to 40º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003eUncontrolled \u0026lt;10º C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eEMI, RFI, EMC\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eStandards compliant\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eConforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable2\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eOptical Power Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDetector Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eInGaAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCalibrated Wavelengths\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e+10 to -52 dBm (850 nm)\u003c\/li\u003e\n\u003cli\u003e+10 to -60 dBm (1300, 1310, 1490, 1550, 1625 nm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Linearity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e±0.2 dB (850 nm)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e±0.1 dB (1300, 1310, 1490, 1550, 1625 nm)\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Uncertainty\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.25 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay Resolution, dB or dBm\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e0.01 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Display Units\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003edBm, mW, μW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto-Wavelength Detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eData Storage\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1000 records, multiple wavelengths per record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eExternal Interface\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eUSB, 2.0 full speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eRemovable adapter, SC adapter as default, optional adapters include LC, ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay update rate\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1 reading per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eReference\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eIndividually set for each wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber ID detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\u0026gt; 50 Hours (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e10, 20, 30 or 60 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, low battery icon blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e11.5 oz (325 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power \u0026lt; -45 dBm\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power \u0026gt; 0 dBm and \u0026lt; -55 dBm\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23°C ±2°C, power level -20dBm, continuous wave, 62.5\/125µm at multi mode wavelengths, 9\/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm,\u003cbr\u003e\u003csup\u003e4\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable3\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eMultimode Optical Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCentral Wavelength\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: +\/-30 nm\u003c\/li\u003e\n\u003cli\u003e1300 nm: +\/- 20 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSpectral Width (FWHM)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: 50 nm (typical)\u003c\/li\u003e\n\u003cli\u003e1300 nm: 135 nm (typical)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMinimum Output Power\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850\/1300 nm:\u003cspan\u003e \u003c\/span\u003e\u003cspan face=\"Arial\" size=\"2\"\u003e\u003cspan face=\"Symbol\" size=\"2\"\u003e³\u003c\/span\u003e\u003cspan size=\"2\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-20 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Output Stability\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.1 dB over 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Can be enabled\/disabled by\u003cspan\u003e \u003c\/span\u003euser.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Output Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Fixed at ID 1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eModes\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eCW, 2 kHz modulated, Auto-wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e40 hrs (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, LED blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1.8 oz (278 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23° C ± 2° C, after 5 minutes warm-up time\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003eauto-wavelength\u003cspan\u003e \u003c\/span\u003emode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable5\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eFindFiber Source Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLaser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSource Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1 through 8.\u003cspan\u003e \u003c\/span\u003eDefault\u003cspan\u003e \u003c\/span\u003eis 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower On\/Low-battery Indicator\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\u0026gt; 80 Hours (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e7.1 in x 1.3 in x 1.0 in (17.9 cm x 3.2 cm x 2.5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e4.4 oz (125 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eSafety\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eMeets Class 1 CDRH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":49450775576872,"sku":"FTK1375","price":5867.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/Untitled_design_-_2025-08-08T110857.221.png?v=1754647752"},{"product_id":"fluke-ftk1475","title":"Fluke Networks Fiber Test Kits - FTK1475","description":"\u003cp\u003eFluke Networks Fiber Test Kits - FTK1475; Complete Fiber Verification Kit with FI-500 FiberInspector Micro – Includes SimpliFiber Pro optical power meter, 850\/1300 multimode source, 1310\/1550 singlemode source, VisiFault VFL, FI-500 FiberInspector, two (2) FindFiber Remote ID sources, and carrying case; SC, ST, and LC power meter adapters, NFC-KIT-BOX fiber optic cleaning kit.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimpliFiber Pro Kit Configurations\u003c\/li\u003e\n\u003cli\u003eFiber Inspection\u003c\/li\u003e\n\u003cli\u003eFiber Cleaning\u003c\/li\u003e\n\u003cli\u003eResults Management\u003c\/li\u003e\n\u003cli\u003eVerify and Locate Faults\u003c\/li\u003e\n\u003cli\u003eUnique Capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable1\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-10º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-20º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e95% (10º C to 35º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003e75% (35º C to 40º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003eUncontrolled \u0026lt;10º C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eEMI, RFI, EMC\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eStandards compliant\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eConforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable2\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eOptical Power Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDetector Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eInGaAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCalibrated Wavelengths\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e+10 to -52 dBm (850 nm)\u003c\/li\u003e\n\u003cli\u003e+10 to -60 dBm (1300, 1310, 1490, 1550, 1625 nm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Linearity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e±0.2 dB (850 nm)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e±0.1 dB (1300, 1310, 1490, 1550, 1625 nm)\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Uncertainty\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.25 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay Resolution, dB or dBm\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e0.01 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Display Units\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003edBm, mW, μW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto-Wavelength Detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eData Storage\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1000 records, multiple wavelengths per record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eExternal Interface\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eUSB, 2.0 full speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eRemovable adapter, SC adapter as default, optional adapters include LC, ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay update rate\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1 reading per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eReference\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eIndividually set for each wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber ID detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\u0026gt; 50 Hours (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e10, 20, 30 or 60 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, low battery icon blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e11.5 oz (325 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power \u0026lt; -45 dBm\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power \u0026gt; 0 dBm and \u0026lt; -55 dBm\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23°C ±2°C, power level -20dBm, continuous wave, 62.5\/125µm at multi mode wavelengths, 9\/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm,\u003cbr\u003e\u003csup\u003e4\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable3\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eMultimode Optical Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCentral Wavelength\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: +\/-30 nm\u003c\/li\u003e\n\u003cli\u003e1300 nm: +\/- 20 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSpectral Width (FWHM)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: 50 nm (typical)\u003c\/li\u003e\n\u003cli\u003e1300 nm: 135 nm (typical)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMinimum Output Power\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850\/1300 nm:\u003cspan\u003e \u003c\/span\u003e\u003cspan face=\"Arial\" size=\"2\"\u003e\u003cspan face=\"Symbol\" size=\"2\"\u003e³\u003c\/span\u003e\u003cspan size=\"2\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-20 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Output Stability\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.1 dB over 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Can be enabled\/disabled by\u003cspan\u003e \u003c\/span\u003euser.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Output Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Fixed at ID 1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eModes\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eCW, 2 kHz modulated, Auto-wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e40 hrs (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, LED blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1.8 oz (278 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23° C ± 2° C, after 5 minutes warm-up time\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003eauto-wavelength\u003cspan\u003e \u003c\/span\u003emode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable4\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eSinglemode Optical Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1310 nm\/1550 nm: dual FP laser\u003cbr\u003e1490 nm\/1625 nm: dual DFB laser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCentral wavelength\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm: ±20 nm\u003c\/li\u003e\n\u003cli\u003e1550 nm: ±30 nm\u003c\/li\u003e\n\u003cli\u003e1490 nm: ±3 nm\u003c\/li\u003e\n\u003cli\u003e1625 nm: ±5 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm: +\/- 20 nm\u003c\/li\u003e\n\u003cli\u003e1550 nm: +\/- 30 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSpectral width (RMS)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm: 2 nm (maximum)\u003c\/li\u003e\n\u003cli\u003e1550 nm: 3 nm (maximum)\u003c\/li\u003e\n\u003cli\u003e1490 nm\/1625 nm: 1 nm (maximum)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMinimum output power\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1310\/1550 nm ≥ -7dBm (typical)\u003cbr\u003e1490 nm\/1625 nm: ≥ -3 dBm (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Output Stability\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.25 dB over 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Can be enabled or disabled by\u003cspan\u003e \u003c\/span\u003euser.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLaunch Condition\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e9\/125 μm\u003cspan\u003e \u003c\/span\u003efibre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1310\/1550 source is fixed at ID 2\u003cbr\u003e1490 nm\/1625 nm is fixed at ID 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eModes\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eCW, 2 kHz modulated, Auto-wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 hrs (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes (can be enabled or disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED blinks.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e9.8 oz (278 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23° C ± 2° C, after 5 minutes warm-up time\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003eauto-wavelength\u003cspan\u003e \u003c\/span\u003emode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable5\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eFindFiber Source Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLaser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSource Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1 through 8.\u003cspan\u003e \u003c\/span\u003eDefault\u003cspan\u003e \u003c\/span\u003eis 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower On\/Low-battery Indicator\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\u0026gt; 80 Hours (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e7.1 in x 1.3 in x 1.0 in (17.9 cm x 3.2 cm x 2.5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e4.4 oz (125 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eSafety\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eMeets Class 1 CDRH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":49450778919208,"sku":"FTK1475","price":8889.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/Fn-4812160-ftk1475_01a_moa.jpg?v=1723108971"},{"product_id":"fluke-ftk2000","title":"Fluke Networks Fiber Test Kits - FTK2000","description":"\u003cp\u003e\u003cspan\u003eFluke Networks Fiber Test Kits - FTK2000; Singlemode Fiber Verification Kit – Includes SimpliFiber Pro optical power meter, 1310\/1550 singlemode source, carrying case, and SC power-meter adapter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cstrong\u003eGot any questions about the Fluke Networks Fiber Test Kits - FTK2000? Please call our team for help during office hours on 01403 756588\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimpliFiber Pro Kit Configurations\u003c\/li\u003e\n\u003cli\u003eResults Management\u003c\/li\u003e\n\u003cli\u003eUnique Capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable1\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-10º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-20º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e95% (10º C to 35º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003e75% (35º C to 40º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003eUncontrolled \u0026lt;10º C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eEMI, RFI, EMC\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eStandards compliant\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eConforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable2\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eOptical Power Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDetector Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eInGaAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCalibrated Wavelengths\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e+10 to -52 dBm (850 nm)\u003c\/li\u003e\n\u003cli\u003e+10 to -60 dBm (1300, 1310, 1490, 1550, 1625 nm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Linearity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e±0.2 dB (850 nm)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e±0.1 dB (1300, 1310, 1490, 1550, 1625 nm)\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Uncertainty\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.25 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay Resolution, dB or dBm\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e0.01 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Display Units\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003edBm, mW, μW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto-Wavelength Detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eData Storage\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1000 records, multiple wavelengths per record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eExternal Interface\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eUSB, 2.0 full speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eRemovable adapter, SC adapter as default, optional adapters include LC, ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay update rate\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1 reading per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eReference\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eIndividually set for each wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber ID detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\u0026gt; 50 Hours (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e10, 20, 30 or 60 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, low battery icon blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e11.5 oz (325 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power \u0026lt; -45 dBm\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power \u0026gt; 0 dBm and \u0026lt; -55 dBm\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23°C ±2°C, power level -20dBm, continuous wave, 62.5\/125µm at multi mode wavelengths, 9\/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm,\u003cbr\u003e\u003csup\u003e4\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable4\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eSinglemode Optical Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1310 nm\/1550 nm: dual FP laser\u003cbr\u003e1490 nm\/1625 nm: dual DFB laser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCentral wavelength\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm: ±20 nm\u003c\/li\u003e\n\u003cli\u003e1550 nm: ±30 nm\u003c\/li\u003e\n\u003cli\u003e1490 nm: ±3 nm\u003c\/li\u003e\n\u003cli\u003e1625 nm: ±5 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm: +\/- 20 nm\u003c\/li\u003e\n\u003cli\u003e1550 nm: +\/- 30 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSpectral width (RMS)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm: 2 nm (maximum)\u003c\/li\u003e\n\u003cli\u003e1550 nm: 3 nm (maximum)\u003c\/li\u003e\n\u003cli\u003e1490 nm\/1625 nm: 1 nm (maximum)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMinimum output power\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1310\/1550 nm ≥ -7dBm (typical)\u003cbr\u003e1490 nm\/1625 nm: ≥ -3 dBm (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Output Stability\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.25 dB over 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Can be enabled or disabled by\u003cspan\u003e \u003c\/span\u003euser.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLaunch Condition\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e9\/125 μm\u003cspan\u003e \u003c\/span\u003efibre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1310\/1550 source is fixed at ID 2\u003cbr\u003e1490 nm\/1625 nm is fixed at ID 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eModes\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eCW, 2 kHz modulated, Auto-wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 hrs (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes (can be enabled or disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED blinks.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e9.8 oz (278 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23° C ± 2° C, after 5 minutes warm-up time\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003eauto-wavelength\u003cspan\u003e \u003c\/span\u003emode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":49450780066088,"sku":"FTK2000","price":3643.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/Untitled_design_-_2025-08-08T110539.609.png?v=1754647571"},{"product_id":"fluke-ms2-ftk","title":"Fluke Networks MicroScanner 2 Cable Verifier - MS2-FTK","description":"\u003cdiv\u003e\n\u003ch2\u003e\u003cspan\u003eMicroScanner (MS2-100) and SimpliFiber Pro (FTK1000) Fibre Test Kit\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe MS2 cable verifier kit contains a MicroScanner (MS2-100) and SimpliFiber Pro (FTK1000)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe MicroScanner\u003cspan\u003e 2\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eCable Verifier presents is a revolutionary voice, data, and video cable tester. It starts by taking results from what was four different test modes and displaying them all at once – graphical wiremap, pair lengths, distance to fault, cable ID, and far end device. What’s more, its integrated RJ11, RJ45, and coax cable test ports support virtually any type of low-voltage cable testing with no need for awkward adapters. The end result is reduced test time and technician error. That makes high-quality installations more efficient than ever.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRevolutionary Interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– graphical\u003cspan\u003e \u003c\/span\u003ewiremap, length, cable ID, and distance to fault displayed on one screen.\u003c\/li\u003e\n\u003cli\u003e\u003cspan id=\"_lblAtAGlanceContent\"\u003e\u003cstrong\u003eMultimedia Support\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– tests all common media types including RJ11, RJ45, Coax, with no need for adapters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan id=\"_lblAtAGlanceContent\"\u003e\u003cstrong\u003eIntelliTone Toning\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– trace virtually any cable or wire pair with IntelliTone digital and analogue toning\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan id=\"_lblAtAGlanceContent\"\u003e\u003cstrong\u003eVDV Service Detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– verifies today’s media services, including 10\/100\/1000 Ethernet, POTS, and PoE\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan id=\"_lblAtAGlanceContent\"\u003e\u003cstrong\u003eRugged Housing –\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrated rubber holster enhances grip and makes it durable enough for the toughest jobs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan id=\"_lblAtAGlanceContent\"\u003e\u003cstrong\u003eOversized Display\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– large, backlit LCD makes results crystal clear whether in bright sunshine or in a dark closet\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003ePerfect as a copper cable tester, copper cabling troubleshooting tool and as a wiremap tester.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRevolutionary Interface\u003c\/li\u003e\n\u003cli\u003eMultimedia Support\u003c\/li\u003e\n\u003cli\u003eIntelliTone Toning\u003c\/li\u003e\n\u003cli\u003eVDV Service Detection\u003c\/li\u003e\n\u003cli\u003eRugged Housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" width=\"100%\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable0\" bordercolor=\"#000000\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eTest Connectors\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eTwisted-pair: UTP, FTP, SSTP 8-pin modular jack accepts 8-pin modular (RJ45) and 4-pin modular (RJ11) plugs; Coax: F-connector for 75 Ω, 50 Ω, 93 Ω cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eCable Tests\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003eLength (460 m or 1500 ft. with resolution to 0.3 m or 1 ft.),\u003cspan\u003e \u003c\/span\u003ewiremap\u003cspan\u003e \u003c\/span\u003eto TIA-568A\/B standards, remote ID locators; displays results on one screen\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eTone Generator\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003eIntelliTone digital tone: [500 KHz]; analog tones: [400Hz, 1KHz]\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003ePoE Detection\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003eSolicits and detects the presence of 802.3af compatible PoE (Power over Ethernet) devices\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eEthernet Port Test\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003eAdvertised speed of 802.3 Ethernet ports (10\/100\/1000)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003ePower Source\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003eBattery type: 2 AA (NEDA 15A, IEC LR6) alkaline batteries\u003cbr\u003eBattery life: 20 hours of typical use\u003cbr\u003eOther compatible battery types: 2 AA photo lithium, NIMH, NICAD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e3 in x 6.4” x 1.4 in (7.6 cm x 16.3 cm x 3.6 cm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e0.8 lbs. (363 grams)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003eMonochrome liquid crystal display (LCD) with backlight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003eUser-configurable NVP for twisted pair and coax; determines actual NVP with known length of cable\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e32 °F to 113 °F (0 oC to 45 oC)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eStorage Temperature\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e-4 °F to +140 °F (-20\u003cspan\u003e \u003c\/span\u003eoC\u003cspan\u003e \u003c\/span\u003eto +60\u003cspan\u003e \u003c\/span\u003eoC)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eOperating Humidity\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e90 % (50 °F to 95 °F; 10 oC to 35 oC)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003e(%RH without condensing)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e75 % (95 °F to 113 °F; 35 oC to 45 oC)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003e\u003cstrong\u003eShock Vibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eMeets requirements for MIL-PRF-28800F for Class 2 random vibration; 1 m drop test with and without\u003cspan\u003e \u003c\/span\u003ewiremap\u003cspan\u003e \u003c\/span\u003eadapter attached\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eEN 61010-1 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003e\u003cstrong\u003eAltitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e4000 m; Storage: 12000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eEN 61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003e\u003cstrong\u003eAgency Certifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eN10140 C-Tick EMC standard; FCC Part 15 Class A; CE European Union Directives Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eOne year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":49450915299624,"sku":"MS2-FTK","price":3480.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/Untitled_design_-_2025-08-08T113913.076.png?v=1754649566"},{"product_id":"fluke-sfmultimodesource","title":"Fluke Networks SimpliFiber® Pro Optical Power Meter - SFMULTIMODESOURCE","description":"\u003cp\u003e\u003cstrong\u003eSimpliFiber® Pro Optical Power Meter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the specifications tab for full details.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #0000ff;\"\u003eGot any questions about the Fluke Networks SimpliFiber® Pro Optical Power Meter? Then call one of our team on 01403 756588\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimpliFiber Pro Kit Configurations\u003c\/li\u003e\n\u003cli\u003eFiber Inspection\u003c\/li\u003e\n\u003cli\u003eFiber Cleaning\u003c\/li\u003e\n\u003cli\u003eResults Management\u003c\/li\u003e\n\u003cli\u003eVerify and Locate Faults\u003c\/li\u003e\n\u003cli\u003eUnique Capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable1\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-10º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-20º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e95% (10º C to 35º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003e75% (35º C to 40º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003eUncontrolled \u0026lt;10º C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eEMI, RFI, EMC\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eStandards compliant\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eConforms to relevant European Union directives; relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable3\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eMultimode Optical Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCentral Wavelength\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: +\/-30 nm\u003c\/li\u003e\n\u003cli\u003e1300 nm: +\/- 20 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSpectral Width (FWHM)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: 50 nm (typical)\u003c\/li\u003e\n\u003cli\u003e1300 nm: 135 nm (typical)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMinimum Output Power\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850\/1300 nm:\u003cspan\u003e \u003c\/span\u003e\u003cspan face=\"Arial\" size=\"2\"\u003e\u003cspan face=\"Symbol\" size=\"2\"\u003e³\u003c\/span\u003e\u003cspan size=\"2\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-20 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Output Stability\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.1 dB over 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Can be enabled\/disabled by\u003cspan\u003e \u003c\/span\u003euser.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Output Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Fixed at ID 1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eModes\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eCW, 2 kHz modulated, Auto-wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e40 hrs (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, LED blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1.8 oz (278 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23° C ± 2° C, after 5 minutes warm-up time\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003eauto-wavelength\u003cspan\u003e \u003c\/span\u003emode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":49450980114728,"sku":"SFMULTIMODESOURCE","price":1308.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/Untitled_design_-_2025-08-08T113452.043.png?v=1754649301"},{"product_id":"fluke-sfpowermeter","title":"Fluke Networks SimpliFiber® Pro Optical Power Meter - SFPOWERMETER","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSimpliFiber® Pro Optical Power Meter\u003c\/strong\u003e\u003cspan\u003e - SFPOWERMETER is a s\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003eimple-to-use fibre-loss tester with advanced time-saving features. \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eVarious kits available with configurations to meet your fibre verification, inspection, and cleaning needs.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimpliFiber Pro Kit Configurations\u003c\/li\u003e\n\u003cli\u003eFiber Inspection\u003c\/li\u003e\n\u003cli\u003eFiber Cleaning\u003c\/li\u003e\n\u003cli\u003eResults Management\u003c\/li\u003e\n\u003cli\u003eVerify and Locate Faults\u003c\/li\u003e\n\u003cli\u003eUnique Capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable1\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-10º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-20º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e95% (10º C to 35º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003e75% (35º C to 40º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003eUncontrolled \u0026lt;10º C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eEMI, RFI, EMC\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eStandards compliant\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eConforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable2\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eOptical Power Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDetector Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eInGaAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCalibrated Wavelengths\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e+10 to -52 dBm (850 nm)\u003c\/li\u003e\n\u003cli\u003e+10 to -60 dBm (1300, 1310, 1490, 1550, 1625 nm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Linearity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e±0.2 dB (850 nm)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e±0.1 dB (1300, 1310, 1490, 1550, 1625 nm)\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Uncertainty\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.25 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay Resolution, dB or dBm\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e0.01 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Display Units\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003edBm, mW, μW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto-Wavelength Detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eData Storage\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1000 records, multiple wavelengths per record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eExternal Interface\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eUSB, 2.0 full speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eRemovable adapter, SC adapter as default, optional adapters include LC, ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay update rate\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1 reading per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eReference\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eIndividually set for each wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber ID detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\u0026gt; 50 Hours (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e10, 20, 30 or 60 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, low battery icon blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e11.5 oz (325 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csup\u003e\u003cbr\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power \u0026lt; -45 dBm\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power \u0026gt; 0 dBm and \u0026lt; -55 dBm\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23°C ±2°C, power level -20dBm, continuous wave, 62.5\/125µm at multi mode wavelengths, 9\/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm,\u003cbr\u003e\u003csup\u003e4\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable3\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCentral Wavelength\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: +\/-30 nm\u003c\/li\u003e\n\u003cli\u003e1300 nm: +\/- 20 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSpectral Width (FWHM)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: 50 nm (typical)\u003c\/li\u003e\n\u003cli\u003e1300 nm: 135 nm (typical)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMinimum Output Power\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850\/1300 nm:\u003cspan\u003e \u003c\/span\u003e\u003cspan face=\"Arial\" size=\"2\"\u003e\u003cspan face=\"Symbol\" size=\"2\"\u003e³\u003c\/span\u003e\u003cspan size=\"2\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-20 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Output Stability\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.1 dB over 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Can be enabled\/disabled by\u003cspan\u003e \u003c\/span\u003euser.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Output Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Fixed at ID 1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eModes\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eCW, 2 kHz modulated, Auto-wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e40 hrs (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, LED blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1.8 oz (278 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23° C ± 2° C, after 5 minutes warm-up time\u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003eauto-wavelength\u003cspan\u003e \u003c\/span\u003emode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":49450981359912,"sku":"SFPOWERMETER","price":1420.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/Untitled_design_-_2025-08-08T113251.435.png?v=1754649193"},{"product_id":"fluke-sfsinglemodesource","title":"Fluke Networks SimpliFiber® Pro Optical Power Meter - SFSINGLEMODESOURCE","description":"\u003cp\u003e\u003cspan\u003eFluke Networks singlemode laser light source for the \u003c\/span\u003eSimpliFiber® series.\u003c\/p\u003e\n\u003cp\u003eCheck the Part Number and Specifications tab for full details.\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cstrong\u003eGot any questions? \u003c\/strong\u003e\u003cstrong\u003eCall 01403 756588 during office hours to speak to a team member.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimpliFiber Pro Kit Configurations\u003c\/li\u003e\n\u003cli\u003eFiber Inspection\u003c\/li\u003e\n\u003cli\u003eFiber Cleaning\u003c\/li\u003e\n\u003cli\u003eResults Management\u003c\/li\u003e\n\u003cli\u003eVerify and Locate Faults\u003c\/li\u003e\n\u003cli\u003eUnique Capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable1\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-10º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-20º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e95% (10º C to 35º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003e75% (35º C to 40º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003eUncontrolled \u0026lt;10º C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eEMI, RFI, EMC\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eStandards compliant\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eConforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable4\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eSinglemode Optical Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1310 nm\/1550 nm: dual FP laser\u003cbr\u003e1490 nm\/1625 nm: dual DFB laser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCentral wavelength\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm: ±20 nm\u003c\/li\u003e\n\u003cli\u003e1550 nm: ±30 nm\u003c\/li\u003e\n\u003cli\u003e1490 nm: ±3 nm\u003c\/li\u003e\n\u003cli\u003e1625 nm: ±5 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm: +\/- 20 nm\u003c\/li\u003e\n\u003cli\u003e1550 nm: +\/- 30 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSpectral width (RMS)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm: 2 nm (maximum)\u003c\/li\u003e\n\u003cli\u003e1550 nm: 3 nm (maximum)\u003c\/li\u003e\n\u003cli\u003e1490 nm\/1625 nm: 1 nm (maximum)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMinimum output power\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1310\/1550 nm ≥ -7dBm (typical)\u003cbr\u003e1490 nm\/1625 nm: ≥ -3 dBm (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Output Stability\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.25 dB over 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Can be enabled or disabled by\u003cspan\u003e \u003c\/span\u003euser.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLaunch Condition\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e9\/125 μm\u003cspan\u003e \u003c\/span\u003efibre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1310\/1550 source is fixed at ID 2\u003cbr\u003e1490 nm\/1625 nm is fixed at ID 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eModes\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eCW, 2 kHz modulated, Auto-wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 hrs (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes (can be enabled or disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED blinks.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e9.8 oz (278 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csup\u003e\u003cbr\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23° C ± 2° C, after 5 minutes warm-up time\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003eauto-wavelength\u003cspan\u003e \u003c\/span\u003emode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":49450983948584,"sku":"SFSINGLEMODESOURCE","price":2545.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/Untitled_design_-_2025-08-08T113038.058.png?v=1754649053"},{"product_id":"fluke-networks-certifiber-pro-cfp-100-m-1","title":"Fluke Networks CertiFiber® Pro with Gold Support- CFP2-100-Q-GLD","description":"\u003cp\u003e\u003cspan\u003eThe Fluke Networks CertiFiber ProQ improves the efficiency of fibre optics certification and includes 1 Versiv Mainframe \u0026amp; Remote and 2 CertiFiber Pro Multimode OLTS Modules. The Taptive user interface simplifies set-up, eliminates errors and speeds troubleshooting. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eVersiv enables users to accomplish more than ever before with a cable tester, accelerating every step of the testing process\u003c\/li\u003e\n\u003cli\u003eProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time.\u003c\/li\u003e\n\u003cli\u003eTaptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels.\u003c\/li\u003e\n\u003cli\u003eLinkWare management software provides unmatched analysis of test results and professional test reports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eCertiFiber Pro’s Optical Loss Test Set (OLTS) double ended fibre optic inspection capability allows you to inspect and certify fiber optic connector end-faces at both ends of your fiber link in less than a second so you can get your job done the first time. This double ended fibre optic inspection capability provides automated PASS\/FAIL certification, takes the guesswork out of fibre inspection so anyone can be a fiber expert.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eGot any questions? \u003c\/strong\u003e\u003cstrong\u003eCall 01403 756588 during office hours to speak to a team member about the Fluke Networks CertiFibre Pro.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOptical loss test set with fastest time to certify – two fibres at two wavelengths in three seconds.\u003c\/li\u003e\n\u003cli\u003eEncircled Flux compliant as required by ANSI\/TIA and ISO\/IEC\u003c\/li\u003e\n\u003cli\u003eMerged Tier 1 (Basic) \/ Tier 2 (Extended) testing and reporting when paired with OptiFiber® Pro OTDR\u003c\/li\u003e\n\u003cli\u003eProjX™ management system ensures all jobs are completed correctly and efficiently\u003c\/li\u003e\n\u003cli\u003eOptical loss test set provides automatic Pass\/Fail analysis to industry standards or custom test limits\u003c\/li\u003e\n\u003cli\u003eDouble ended Pass\/Fail certification of fibre optic connector end faces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" id=\"ui-accordion-1-panel-0\" aria-labelledby=\"ui-accordion-1-header-0\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" aria-labelledby=\"ui-accordion-1-header-1\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" id=\"ui-accordion-1-panel-5\" aria-labelledby=\"ui-accordion-1-header-5\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ctable border=\"0\" cellpadding=\"2\" cellspacing=\"0\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#cccccc\" colspan=\"2\"\u003e\u003cstrong\u003ePower Meter Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003eInput Connector\u003c\/td\u003e\n\u003ctd\u003eInterchangeable connector adapter (LC standard, SC, ST and FC optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003eDetector Type\u003c\/td\u003e\n\u003ctd\u003eInGaAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003eWavelengths\u003c\/td\u003e\n\u003ctd\u003e850 nm, 1300 nm, 1310 nm, 1550 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003ePower Measurement Range\u003c\/td\u003e\n\u003ctd\u003e0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003ePower Measurement Uncertainty\u003csup\u003e1,2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; +\/- 5% +\/- 32 pW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003eMeasurement Linearity\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; ± 0.1 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003eRe-calibration Period\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003eIntegrated Wi-Fi\u003c\/td\u003e\n\u003ctd\u003eMeets IEEE 802.11 a\/b\/g\/n; dual band (2.4 GHz and 5 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan class=\"legal\"\u003e\u003cspan size=\"1\" style=\"font-size: xx-small;\"\u003e1. +\/- 100 pW at 850 nm\u003cbr\u003e2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50\/125 μm and NA = 0.14 for 9\/125 μm. Ambient temperature 23° ± 1°C. SC\/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST.\u003cbr\u003e3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5 minute warm-up.\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":49450633822504,"sku":"CFP2-100-Q-GLD","price":14817.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/Untitled_design_-_2025-08-11T093328.735.png?v=1754901230"},{"product_id":"fluke-networks-certifiber®-pro-cfp2-100-m","title":"Fluke Networks CertiFiber® Pro - CFP2-100-M-INT","description":"\u003cp\u003e\u003cspan\u003eThe Fluke Networks CertiFiber ProQI improves the efficiency of fibre optics certification and includes 1 Versiv Mainframe \u0026amp; Remote and 2 CertiFiber Pro Singlemode OLTS modules. The Taptive user interface simplifies set-up, eliminates errors and speeds troubleshooting. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eVersiv enables users to accomplish more than ever before with a cable tester, accelerating every step of the testing process\u003c\/li\u003e\n\u003cli\u003eProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time.\u003c\/li\u003e\n\u003cli\u003eTaptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels.\u003c\/li\u003e\n\u003cli\u003eLinkWare management software provides unmatched analysis of test results and professional test reports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eCertiFiber Pro’s Optical Loss Test Set (OLTS) double ended fibre optic inspection capability allows you to inspect and certify fiber optic connector end-faces at both ends of your fiber link in less than a second so you can get your job done the first time. This double ended fibre optic inspection capability provides automated PASS\/FAIL certification, takes the guesswork out of fibre inspection so anyone can be a fiber expert.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eGot any questions? \u003c\/strong\u003e\u003cstrong\u003eCall 01403 756588 during office hours to speak to a team member about the Fluke Networks CertiFibre Pro.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOptical loss test set with fastest time to certify – two fibres at two wavelengths in three seconds.\u003c\/li\u003e\n\u003cli\u003eEncircled Flux compliant as required by ANSI\/TIA and ISO\/IEC\u003c\/li\u003e\n\u003cli\u003eMerged Tier 1 (Basic) \/ Tier 2 (Extended) testing and reporting when paired with OptiFiber® Pro OTDR\u003c\/li\u003e\n\u003cli\u003eProjX™ management system ensures all jobs are completed correctly and efficiently\u003c\/li\u003e\n\u003cli\u003eOptical loss test set provides automatic Pass\/Fail analysis to industry standards or custom test limits\u003c\/li\u003e\n\u003cli\u003eDouble ended Pass\/Fail certification of fibre optic connector end faces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" id=\"ui-accordion-1-panel-0\" aria-labelledby=\"ui-accordion-1-header-0\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" aria-labelledby=\"ui-accordion-1-header-1\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" id=\"ui-accordion-1-panel-5\" aria-labelledby=\"ui-accordion-1-header-5\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ctable border=\"0\" cellpadding=\"2\" cellspacing=\"0\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#cccccc\" colspan=\"2\"\u003e\u003cstrong\u003ePower Meter Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003eInput Connector\u003c\/td\u003e\n\u003ctd\u003eInterchangeable connector adapter (LC standard, SC, ST and FC optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003eDetector Type\u003c\/td\u003e\n\u003ctd\u003eInGaAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003eWavelengths\u003c\/td\u003e\n\u003ctd\u003e850 nm, 1300 nm, 1310 nm, 1550 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003ePower Measurement Range\u003c\/td\u003e\n\u003ctd\u003e0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003ePower Measurement Uncertainty\u003csup\u003e1,2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; +\/- 5% +\/- 32 pW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003eMeasurement Linearity\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; ± 0.1 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003eRe-calibration Period\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003eIntegrated Wi-Fi\u003c\/td\u003e\n\u003ctd\u003eMeets IEEE 802.11 a\/b\/g\/n; dual band (2.4 GHz and 5 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan class=\"legal\"\u003e\u003cspan size=\"1\" style=\"font-size: xx-small;\"\u003e1. +\/- 100 pW at 850 nm\u003cbr\u003e2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50\/125 μm and NA = 0.14 for 9\/125 μm. Ambient temperature 23° ± 1°C. SC\/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST.\u003cbr\u003e3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5 minute warm-up.\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":49450745757992,"sku":"CFP2-100-M-INT","price":10588.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/Fn-cfp-100-m_79d3467d-5479-4f91-a384-c81f49f4492b.jpg?v=1724938959"},{"product_id":"fluke-networks-certifiber®-max-optical-loss-test-set","title":"CertiFiber Max Single-mode OLTS Test Set with two Versiv Mains","description":"\u003ch4\u003e\u003cspan\u003eCertiFiber Max Single-mode OLTS Test Set with two Versiv Mains. \u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIncludes:\u003c\/strong\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e2 Versiv Main units including Wi-Fi, \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e2 Hand Straps \u0026amp; 2 Shoulder Straps \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUSB Interface Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e2 AC Chargers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo CertiFiber™ Max single-mode modules with MPO 12 pinned UniPort™ adapters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMPO 16 pinned output ports\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLC input ports plus test reference cord with connectors for main unit source and meter ports and connection to cable under test\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSecond test reference cord with connectors for remote unit source and meter ports and connection to cable under test\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e1 verification cord and 2 MPO 12 couplers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVersiv-XL cube case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eZippered Test Reference Cord case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUniPort case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSafety card, Quick Reference Guide, warranty card and statement of calibration\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51395145597224,"sku":"CFM-100S","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/CFM-100S_c487a2a7-2ccf-46f4-8e70-b9584f9c2c9d.png?v=1770220769"},{"product_id":"fluke-networks-uniport™-adapter-and-cord-set","title":"Fluke Networks UniPort™ Adapter and Cord Set","description":"\u003cp\u003e\u003cstrong\u003eCFM-EXPAND-S-MPO12\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUniPort™adapter and cord set for testing MPO 12 pinned and unpinned single-mode cables includes two pinned and two unpinned UniPort™ adapters for CertiFiber Max; four test reference cords with connectors for main unit source and meter ports and connection to cable under test (one each pinned main, pinned remote, unpinned main, and pinned remote); one pinned and one unpinned verification cord and two couplers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCFM-EXPAND-S-MPO16\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUniPort™adapter and cord set for testing MPO 16 pinned and unpinned single-mode cables includes two pinned and two unpinned UniPort™ adapters for CertiFiber Max; four test reference cords with connectors for main unit source and meter ports and connection to cable under test (one each pinned main, pinned remote, unpinned main, and pinned remote); one pinned and one unpinned verification cord and two couplers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCFM-EXPAND-S-MPO24\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUniPort™adapter and cord set for testing MPO 24 pinned and unpinned single-mode cables includes two pinned and two unpinned UniPort™ adapters for CertiFiber Max; four test reference cords with connectors for main unit source and meter ports and connection to cable under test (one each pinned main, pinned remote, unpinned main, and pinned remote); one pinned and one unpinned verification cord and two couplers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCFM-EXPAND-S-MMC16\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUniPort™adapter and cord set for testing MMC 16 pinned and unpinned single-mode cables includes two pinned and two unpinned UniPort™ adapters for CertiFiber Max; four test reference cords with connectors for main unit source and meter ports and connection to cable under test (one each pinned main, pinned remote, unpinned main, and pinned remote); one pinned and one unpinned verification cord and two couplers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCFM-EXPAND-S-MMC24\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUniPort™adapter and cord set for testing MMC 24 pinned and unpinned single-mode cables includes two pinned and two unpinned UniPort™ adapters for CertiFiber Max; four test reference cords with connectors for main unit source and meter ports and connection to cable under test (one each pinned main, pinned remote, unpinned main, and pinned remote); one pinned and one unpinned verification cord and two couplers.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Fluke Networks","offers":[{"title":"MPO12","offer_id":51397178917160,"sku":"CFM-EXPAND-S-MPO12","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MPO16","offer_id":51397178949928,"sku":"CFM-EXPAND-S-MPO16","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MPO24","offer_id":51397178982696,"sku":"CFM-EXPAND-S-MPO24","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MMC16","offer_id":51397179015464,"sku":"CFM-EXPAND-S-MMC16","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MMC24","offer_id":51397179048232,"sku":"CFM-EXPAND-S-MMC24","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/CFM-EXPAND-S-MMC16_776b855f-a0a0-4913-8ab7-3cfaddfa6c55.png?v=1770202905"},{"product_id":"fluke-networks-reference-cord-set","title":"Fluke Networks Reference Cord Set","description":"\u003cp\u003e\u003cstrong\u003eCFM-TRC-S-MPO12U\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eReference cord set for testing MPO 12 pinned single-mode cables includes test reference cord with connectors for main unit source and meter ports and connection to cable under test; second test reference cord with connectors for remote unit source and meter ports and connection to cable under test.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCFM-TRC-S-MPO16U\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eReference cord set for testing MPO 16 pinned single-mode cables includes test reference cord with connectors for main unit source and meter ports and connection to cable under test; second test reference cord with connectors for remote unit source and meter ports and connection to cable under test.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCFM-TRC-S-MPO24U\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eReference cord set for testing MPO 24 pinned single-mode cables includes test reference cord with connectors for main unit source and meter ports and connection to cable under test; second test reference cord with connectors for remote unit source and meter ports and connection to cable under test.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCFM-TRC-S-MMC16U\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eReference cord set for testing MMC 16 pinned single-mode cables includes test reference cord with connectors for main unit source and meter ports and connection to cable under test; second test reference cord with connectors for remote unit source and meter ports and connection to cable under test.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCFM-TRC-S-MMC24U\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eReference cord set for testing MMC 24 pinned single-mode cables includes test reference cord with connectors for main unit source and meter ports and connection to cable under test; second test reference cord with connectors for remote unit source and meter ports and connection to cable under test.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCFM-TRC-S-MPO12P\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eReference cord set for testing MPO 12 unpinned single-mode cables includes test reference cord with connectors for main unit source and meter ports and connection to cable under test; second test reference cord with connectors for remote unit source and meter ports and connection to cable under test.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCFM-TRC-S-MPO16P\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eReference cord set for testing MPO 16 unpinned single-mode cables includes test reference cord with connectors for main unit source and meter ports and connection to cable under test; second test reference cord with connectors for remote unit source and meter ports and connection to cable under test.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCFM-TRC-S-MPO24P\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eReference cord set for testing MPO 24 unpinned single-mode cables includes test reference cord with connectors for main unit source and meter ports and connection to cable under test; second test reference cord with connectors for remote unit source and meter ports and connection to cable under test.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCFM-TRC-S-MMC16P\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eReference cord set for testing MMC 16 unpinned single-mode cables includes test reference cord with connectors for main unit source and meter ports and connection to cable under test; second test reference cord with connectors for remote unit source and meter ports and connection to cable under test.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCFM-TRC-S-MMC24P\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eReference cord set for testing MMC 24 unpinned single-mode cables includes test reference cord with connectors for main unit source and meter ports and connection to cable under test; second test reference cord with connectors for remote unit source and meter ports and connection to cable under test.\u003c\/span\u003e\u003c\/p\u003e","brand":"Fluke Networks","offers":[{"title":"MPO12 \/ Pinned","offer_id":51397199823144,"sku":"CFM-TRC-S-MPO12U","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MPO12 \/ Unpinned","offer_id":51397225021736,"sku":"CFM-TRC-S-MPO12P","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MPO16 \/ Pinned","offer_id":51397199855912,"sku":"CFM-TRC-S-MPO16U","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MPO16 \/ Unpinned","offer_id":51397225054504,"sku":"CFM-TRC-S-MPO16P","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MPO24 \/ Pinned","offer_id":51397199888680,"sku":"CFM-TRC-S-MPO24U","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MPO24 \/ Unpinned","offer_id":51397225087272,"sku":"CFM-TRC-S-MPO24P","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MMC16 \/ Pinned","offer_id":51397199921448,"sku":"CFM-TRC-S-MMC16U","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MMC16 \/ Unpinned","offer_id":51397225120040,"sku":"CFM-TRC-S-MMC16P","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MMC24 \/ Pinned","offer_id":51397199954216,"sku":"CFM-TRC-S-MMC24U","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MMC24 \/ Unpinned","offer_id":51397225152808,"sku":"CFM-TRC-S-MMC24P","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/CFM-TRC-S-MPO12U_cd6da019-9161-4b0a-b9e6-3823a3a19925.png?v=1770203922"},{"product_id":"fluke-networks-verification-cord-set","title":"Fluke Networks Verification Cord Set","description":"\u003cp\u003e\u003cstrong\u003eTRC-SM-VERIFY-MPO12P\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMPO 12 pinned one meter single-mode jumper cable and two couplers for verifying reference setting in CertiFiber Max.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTRC-SM-VERIFY-MPO16P\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMPO 16 pinned one meter single-mode jumper cable and two couplers for verifying reference setting in CertiFiber Max.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTRC-SM-VERIFY-MPO24P\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMPO 24 pinned one meter single-mode jumper cable and two couplers for verifying reference setting in CertiFiber Max.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTRC-SM-VERIFY-MMC16P\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMMC 16 pinned one meter single-mode jumper cable and two couplers for verifying reference setting in CertiFiber Max.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTRC-SM-VERIFY-MMC24P\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMMC 24 pinned one meter single-mode jumper cable and two couplers for verifying reference setting in CertiFiber Max.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTRC-SM-VERIFY-MPO12U\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMPO 12 unpinned one meter single-mode jumper cable and two couplers for verifying reference setting in CertiFiber Max.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTRC-SM-VERIFY-MPO16U\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMPO 16 unpinned one meter single-mode jumper cable and two couplers for verifying reference setting in CertiFiber Max.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTRC-SM-VERIFY-MPO24U\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMPO 24 unpinned one meter single-mode jumper cable and two couplers for verifying reference setting in CertiFiber Max. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTRC-SM-VERIFY-MMC16U\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMMC 16 unpinned one meter single-mode jumper cable and two couplers for verifying reference setting in CertiFiber Max.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTRC-SM-VERIFY-MMC24U\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMMC 24 unpinned one meter single-mode jumper cable and two couplers for verifying reference setting in CertiFiber Max. \u003c\/span\u003e\u003c\/p\u003e","brand":"Fluke Networks","offers":[{"title":"MPO12 \/ Pinned","offer_id":51397245731112,"sku":"TRC-SM-VERIFY-MPO12P","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MPO12 \/ Unpinned","offer_id":51397245763880,"sku":"TRC-SM-VERIFY-MPO12U","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MPO16 \/ Pinned","offer_id":51397245796648,"sku":"TRC-SM-VERIFY-MPO16P","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MPO16 \/ Unpinned","offer_id":51397245829416,"sku":"TRC-SM-VERIFY-MPO16U","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MPO24 \/ Pinned","offer_id":51397245862184,"sku":"TRC-SM-VERIFY-MPO24P","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MPO24 \/ Unpinned","offer_id":51397245894952,"sku":"TRC-SM-VERIFY-MPO24U","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MMC16 \/ Pinned","offer_id":51397245927720,"sku":"TRC-SM-VERIFY-MMC16P","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MMC16 \/ Unpinned","offer_id":51397245960488,"sku":"TRC-SM-VERIFY-MMC16U","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MMC24 \/ Pinned","offer_id":51397245993256,"sku":"TRC-SM-VERIFY-MMC24P","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"MMC24 \/ Unpinned","offer_id":51397246026024,"sku":"TRC-SM-VERIFY-MMC24U","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/TRC-SM-VERIFY-MPO12P_855cbaac-06bd-403d-bf44-b8cc91f46b3f.png?v=1770204443"},{"product_id":"certifiber-max-single-mode-olts-test-set-with-two-versiv-mains-inspection-cameras","title":"CertiFiber Max Single-mode OLTS Test Set with two Versiv mains, inspection cameras","description":"\u003ch4\u003e\u003cspan\u003eCertiFiber Max Single-mode OLTS Test Set with two Versiv mains, inspection cameras.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIncludes: \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e2 Versiv Main units including Wi-Fi\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e2 HandStraps and 2 Shoulder Straps\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUSB Interface Cable \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e2 AC Chargers \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo CertiFiber™ Max single-mode modules with MPO 12 pinned UniPort™ adapters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMPO 16 pinned output ports\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLC input ports plus test reference cord with connectors for main unit source and meter ports and connection to cable under test\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSecond test reference cord with connectors for remote unit source and meter ports and connection to cable under test\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e1 verification cord and 2 MPO 12 couplers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e2 each FiberInspector ™ cameras, each with with keyless MPO 12-24 APC tip\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSingle Fiber Adapter for FI-1000 tips\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAC charger\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGetting Started Guide\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHolster\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBox for tip storage\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVersiv-XL cube case,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eZippered Test Reference Cord case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUniPort case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSafety card, Quick Reference Guide, warranty card and statement of calibration.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397675188520,"sku":"CFM-100SI","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/CFM-100SI_ee171ff3-d798-4121-b1e6-e8502a57de91.png?v=1770220829"},{"product_id":"certifiber-max-single-mode-module-set-with-mpo12-test-reference-cords-no-versiv-gold-support","title":"CertiFiber Max Single-mode Module set with MPO12 Test Reference Cords, no Versiv (GOLD SUPPORT)","description":"\u003ch4\u003e\u003cspan\u003eCertiFiber Max Single-mode Module set with MPO12 Test Reference Cords, no Versiv\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eIncludes: \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo CertiFiber™ Max single-mode modules with MPO12 pinned UniPort™ adapters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMPO 16 pinned output ports\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLC input ports plus test reference cord with connectors for main unit source and meter ports and connection to cable under test\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSecond test reference cord with connectors for remote unit source and meter ports and connection to cable under test\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOne verification cord\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e2 MPO12 couplers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVersiv-XL carry case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eZippered test reference cord case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSafety card, Quick Reference Guide, warranty card and statement of calibration.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397675352360,"sku":"CFM-S-ADD","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/CFM-S-ADD_a783bc08-4938-47d4-beac-fabd7984425f.png?v=1770220888"},{"product_id":"certifiber-max-single-mode-olts-replacement-single-module-no-versiv","title":"CertiFiber Max Single-mode OLTS Replacement Single Module, no Versiv","description":"\u003ch4\u003e\u003cspan\u003eCertiFiber Max Single-mode OLTS Replacement Single Module, no Versiv\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eOne CertiFiber™ Max module \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMPO 12 pinned UniPort™ adapter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMPO 16 pinned output port\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLC input port\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397675581736,"sku":"CFM-S-MOD","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/CFM-S-MOD_5559aaf6-886f-4c8f-b0af-fb29772b935a.png?v=1770220935"},{"product_id":"certifiber-max-single-mode-olts-replacement-single-module-no-versiv-copy","title":"CertiFiber Max MM\/SM UniPort Adapter Kit (for testing MPO12 pinned)","description":"\u003ch4\u003e\u003cspan\u003eCertiFiber Max MM\/SM UniPort Adapter Kit (for testing MPO12 pinned)\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo UniPort™ adapters for testing MPO 12 cables\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397678399784,"sku":"NFA-MPO12P-KIT","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/NFA-MPO12P-KIT_c6b47849-69a7-4537-b01e-3bd2029c03ea.png?v=1770221081"},{"product_id":"certifiber-max-mm-sm-uniport-adapter-kit-for-testing-mpo16-pinned","title":"CertiFiber Max MM\/SM UniPort Adapter Kit (for testing MPO16 pinned)","description":"\u003cp\u003e\u003cstrong\u003eCertiFiber Max MM\/SM UniPort Adapter Kit (for testing MPO16 pinned)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo UniPort™ adapters for testing MPO 16 cables\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397678825768,"sku":"NFA-MPO16P-KIT","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/NFA-MPO16P-KIT_556f3bca-c0d4-4c27-a594-1ff9c7eb8568.png?v=1770221157"},{"product_id":"certifiber-max-mm-sm-uniport-adapter-kit-for-testing-mpo24-pinned","title":"CertiFiber Max MM\/SM UniPort Adapter Kit (for testing MPO24 pinned)","description":"\u003ch4\u003e\u003cspan\u003eCertiFiber Max MM\/SM UniPort Adapter Kit (for testing MPO24 pinned)\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIncludes: \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eOne main and one remote UniPort™ adapter for testing MPO 24 cables\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397679546664,"sku":"NFA-MPO24P-KIT","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/NFA-MPO24P-KIT_8e6e0634-78a4-4664-bb5d-a908fd768904.png?v=1770221220"},{"product_id":"certifiber-max-mm-sm-uniport-adapter-kit-for-testing-mmc16-pinned","title":"CertiFiber Max MM\/SM UniPort Adapter Kit (for testing MMC16 pinned)","description":"\u003ch4\u003e\u003cspan\u003eCertiFiber Max MM\/SM UniPort Adapter Kit (for testing MMC16 pinned)\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo UniPort™ adapter sfor testing MMC 16 cables\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397679808808,"sku":"NFA-MMC16P-KIT","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/NFA-MMC16P-KIT_0cd5b8f1-da85-48d9-9d43-dd3970c18aa7.png?v=1770221282"},{"product_id":"certifiber-max-mm-sm-uniport-adapter-kit-for-testing-mmc24-pinned","title":"CertiFiber Max MM\/SM UniPort Adapter Kit (for testing MMC24 pinned)","description":"\u003ch4\u003e\u003cspan\u003eCertiFiber Max MM\/SM UniPort Adapter Kit (for testing MMC24 pinned)\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eOne main and one remote UniPort™ adapter for testing MMC 24 cables\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397680202024,"sku":"NFA-MMC24P-KIT","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/NFA-MMC24P-KIT_dbc864d5-de40-4ea2-a46e-6aef4b30cf3d.png?v=1770221354"},{"product_id":"certifiber-max-mm-sm-uniport-adapter-kit-for-testing-mpo12-unpinned","title":"CertiFiber Max MM\/SM UniPort Adapter Kit (for testing MPO12 unpinned)","description":"\u003ch4\u003e\u003cspan\u003eCertiFiber Max MM\/SM UniPort Adapter Kit (for testing MPO12 unpinned)\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo UniPort™ adapter for testing MPO 12 cables\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397680333096,"sku":"NFA-MPO12U-KIT","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/NFA-MPO12U-KIT_ad2d7d43-0095-4d84-9f7f-612845de5652.png?v=1770221400"},{"product_id":"certifiber-max-mm-sm-uniport-adapter-kit-for-testing-mpo12-unpinned-copy","title":"CertiFiber Max MM\/SM UniPort Adapter Kit (for testing MPO16 unpinned)","description":"\u003ch4\u003e\u003cspan\u003eCertiFiber Max MM\/SM UniPort Adapter Kit (for testing MPO16 unpinned)\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo UniPort™ adapters for testing MPO 16 cables\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397680693544,"sku":"NFA-MPO16U-KIT","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/NFA-MPO16U-KIT_557c8b66-476d-4de1-9708-b15a9d3d1cad.png?v=1770221452"},{"product_id":"certifiber-max-mm-sm-uniport-adapter-kit-for-testing-mpo16-unpinned-copy","title":"CertiFiber Max MM\/SM UniPort Adapter Kit (for testing MPO24 unpinned)","description":"\u003ch4\u003e\u003cspan\u003eCertiFiber Max MM\/SM UniPort Adapter Kit (for testing MPO24 unpinned)\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eOne main and one remote UniPort™ adapter for testing MPO 24 cables\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397681381672,"sku":"NFA-MPO24U-KIT","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/NFA-MPO24U-KIT_79240647-cc17-4329-9363-17eda69deffb.png?v=1770221508"},{"product_id":"certifiber-max-mm-sm-uniport-adapter-kit-for-testing-mmc16-unpinned","title":"CertiFiber Max MM\/SM UniPort Adapter Kit (for testing MMC16 unpinned)","description":"\u003ch4\u003e\u003cspan\u003eCertiFiber Max MM\/SM UniPort Adapter Kit (for testing MMC16 unpinned)\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo UniPort™ adapters for testing MMC 16 cables\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397681709352,"sku":"NFA-MMC16U-KIT","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/NFA-MMC16U-KIT_9b9692ac-b57f-449a-adc6-dbbd30c2efbc.png?v=1770221557"},{"product_id":"certifiber-max-mm-sm-uniport-adapter-kit-for-testing-mmc16-unpinned-copy","title":"CertiFiber Max MM\/SM UniPort Adapter Kit (for testing MMC24 unpinned)","description":"\u003ch4\u003e\u003cspan\u003eCertiFiber Max MM\/SM UniPort Adapter Kit (for testing MMC24 unpinned)\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eOne main and one remote UniPort™ adapter for testing MMC 24 cables\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397682037032,"sku":"NFA-MMC24U-KIT","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/NFA-MMC24U-KIT_5ccbb4e1-8967-4139-8309-b187f60be502.png?v=1770221594"},{"product_id":"one-each-mpo-16-uniport™-single-mode-replacement-adapter-for-certifiber-max-output-port","title":"One each MPO 16 UniPort™ single-mode replacement adapter for CertiFiber Max output port","description":"\u003cp\u003e\u003cspan\u003eOne each MPO 16 UniPort™ single-mode replacement adapter for CertiFiber Max output port.\u003c\/span\u003e\u003c\/p\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397682266408,"sku":"NFA-MPO16P-SM-OUT","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/NFA-MPO16P-SMOUT_0bfc8d89-ae94-4469-b423-a6504bbe5177.png?v=1770221648"},{"product_id":"screw-on-adapter-for-testing-duplex-lc-cables","title":"Screw-on adapter for testing duplex LC cables","description":"\u003cp\u003e\u003cspan\u003eScrew-on adapter for testing duplex LC cables.\u003c\/span\u003e\u003c\/p\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397682463016,"sku":"NFA-CFM-LC","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/NFA-CFM-LC_49973d8f-5ca6-4cc9-897c-c105b31858bb.png?v=1770221709"},{"product_id":"screw-on-adapter-for-testing-duplex-sc-cables","title":"Screw-on adapter for testing duplex SC cables","description":"\u003cp\u003e\u003cspan\u003eScrew-on adapter for testing duplex SC cables.\u003c\/span\u003e\u003c\/p\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397682921768,"sku":"NFA-CFM-SC","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/NFA-CFM-SC_ea2f38f5-04d4-4ac4-bce7-a831738914e9.png?v=1770221752"},{"product_id":"12-24-fiber-mpo-coupler-keyed","title":"12\/24 fiber MPO coupler, keyed","description":"\u003cp\u003e\u003cspan\u003e12\/24 fiber MPO coupler, keyed.\u003c\/span\u003e\u003c\/p\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397682987304,"sku":"ADP-MPO12\/24-A","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/ADP-MPO12_24-A_60db067a-323a-4486-b62f-20777dec29ac.png?v=1770221800"},{"product_id":"16-32-fiber-mpo-coupler-keyed","title":"16\/32 fiber MPO coupler, keyed","description":"\u003cp\u003e\u003cspan\u003e16\/32 fiber MPO coupler, keyed.\u003c\/span\u003e\u003c\/p\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397683118376,"sku":"ADP-MPO16\/32-A","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/ADP-MPO16_32-A_834d64aa-8ba3-455f-9bfb-52d1f2bed63b.png?v=1770221835"},{"product_id":"12-16-24-32-fiber-mmc-coupler","title":"12\/16\/24\/32 fiber MMC coupler","description":"\u003cp\u003e\u003cspan\u003e12\/16\/24\/32 fiber MMC coupler.\u003c\/span\u003e\u003c\/p\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":51397683314984,"sku":"ADP-MMC12TO32-1A","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0810\/5780\/8680\/files\/ADP-MMC12TO32-IA_b8951cf6-4508-4cd7-b46e-4476a709379e.png?v=1770221865"}],"url":"https:\/\/networkscentre.com\/collections\/olts.oembed?page=2","provider":"Networks Centre","version":"1.0","type":"link"}